Marcinek, Saša; Chapoulie, Arnaud; Salaün, Pascal; Smith, Scott; Omanović, Dario (2021) Revised application of copper ion selective electrode (Cu-ISE) in marine waters: A new meta-calibration approach. Talanta, 226 . ISSN 00399140
|
PDF
- Accepted Version
- article
Available under License Creative Commons Attribution Non-commercial No Derivatives. Download (2MB) | Preview |
Abstract
Copper (Cu) is a bio-essential trace element that is of concerns due to its potential toxicity at concentrations commonly encountered in coastal waters. Here, we revisit the applicability of Cu(II) ion selective electrode (Cu-ISE) based on a jalpaite membrane for the measurement of Cufree in seawater. At high total Cu concentration (>0.1 mM), (near)Nernstian slope was obtained and determination of Cufree down to fM levels was possible. However, this slope decreases with decreasing total Cu concentration (e.g. 7 mV/decade at 15 nM total Cu) making the use of a common single calibration approach unreliable. To solve this problem, we carried out several calibrations at different levels of total Cu (15 nM - 1 mM) and ethylenediamine (EN: 5 μM - 15 mM) and fitted the calibration parameters (slope and intercept) as a function of total Cu using the Gompertz function (a meta-calibration approach). The derived empirical equations allowed the determination of Cufree at any total Cu concentration above 20 nM (determination of Cufree at lower total Cu levels is prevented by the dissolution of the electrode). We successfully tested this meta-calibration approach in UV digested seawater in presence of a synthetic ligand (EN), isolated natural organic matter (humic acid, HA) and in a natural estuarine sample. In each case, our meta-calibration approach provided a good agreement with modeled speciation data (Visual MINTEQ), while standard single approach failed. We provide here a new method for the direct determination of the free Cu ion concentration in seawater at levels relevant for coastal waters.
Item Type: | Article | ||||||||
---|---|---|---|---|---|---|---|---|---|
Uncontrolled Keywords: | Copper ion selective electrode; meta-Calibration; Speciation ;Trace metals | ||||||||
Subjects: | NATURAL SCIENCES NATURAL SCIENCES > Chemistry NATURAL SCIENCES > Chemistry > Analytic Chemistry NATURAL SCIENCES > Interdisciplinary Natural Sciences > Marine Science |
||||||||
Divisions: | Division for Marine and Enviromental Research | ||||||||
Projects: |
|
||||||||
Depositing User: | Dario Omanović | ||||||||
Date Deposited: | 08 Dec 2022 10:41 | ||||||||
URI: | http://fulir.irb.hr/id/eprint/7677 | ||||||||
DOI: | 10.1016/j.talanta.2021.122170 |