Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

Scharenberg, L.; Alozy, J.; Angelis, Y.; Aune, S.; Ballabriga, R.; Bortfeldt, J.; Brunbauer, F.; Brunoldi, M.; Campbell, M.; Datta, J.; De Oliveira, R.; Dehmelt, K.; Fanourakis, G.; Fernandez-Tenllado, J.M.; Flöthner, K.J.; Fiorina, D.; Gallinaro, M.; Garcia, F.; Gascon, D.; Giomataris, I.; Gnanvo, K.; Gomez, S.; Iguaz, F.J.; Janssens, D.; Kallitsopoulou, A.; Kovacic, M.; Kross, B.; Legou, P.; Lisowska, M.; Liu, J.; Lupberger, M.; Manera, R.; Maniatis, I.; Mariscal, A.; Mauricio, J.; McKisson, J.; Meng, Y.; Muller, H.; Oliveri, E.; Orlandini, G.; Pandey, A.; Papaevangelou, T.; Picatoste, E.; Piller, M.; Pomorski, M.; Ropelewski, L.; Sampsonidis, D.; Sanuy, A.; Schneider, T.; Scorsone, E.; Sohl, L.; van Stenis, M.; Tsipolitis, Y.; Tzamarias, S.E.; Utrobičić, Antonija; Vai, I.; Veenhof, R.; Vitulo, P.; Wang, X.; White, S.; Xi, W.; Zhang, Z.; Zhou, Y. (2025) Integration of the FastIC front-end electronics into the Picosec MicroMegas detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1076 . ISSN 01689002

[img] PDF - Published Version - article
Available under License Creative Commons Attribution.

Download (1MB)

Abstract

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel frontend electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

Item Type: Article
Uncontrolled Keywords: Gaseous fast-timing detectors; Picosec MicroMegas; FastIC; Precise timing electronics
Subjects: NATURAL SCIENCES > Physics
NATURAL SCIENCES > Physics > Nuclear Physics
Divisions: Division of Experimental Physics
Depositing User: Ema Buhin Šaler
Date Deposited: 04 Mar 2026 13:07
URI: http://fulir.irb.hr/id/eprint/11314